Skip to content
Public template

About

EV Onboard Charger with PFC and LLC Resonant Converter

Resources

Stars

22 stars

Watchers

1 watching

Forks

Latest commit

 

History

183 Commits

Folders and files

NameName
Last commit message
Last commit date
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

7 kW EV On-Board Charger: Totem-Pole PFC + Dual LLC

Important

The PLECS models use the component libraries in Gueni/0000_libraries (Power, Passives, Switches, Magnatic Components, Sensors, CTRL). Get them, and add 0000_libraries/Plecs to the PLECS library path, before opening or running the models.

Design and simulation of a single-phase EV on-board charger: a totem-pole bridgeless PFC with average current mode control feeds a 400 V DC link, and two LLC resonant converters in parallel charge a 250–450 V battery. The PLECS model is built from the library blocks and driven from Python: parameter sweeps, one HTML report with waveforms and harmonics, logs, and optional code generation for a PLECS RT Box. LTspice schematics cover the input filter, the transformer and the LLC stage.

EV OBC block diagram

The signal path is grid → EMI filter → PFC → DC link → dual LLC → DC filter → battery (load). Sensors feed an MCU model (ADC + firmware scaling) that runs the PFC controller; the LLC controller sets the switching frequency from the output voltage.

Specifications

Parameter Value
Output 7 kW, 250–450 V DC (nominal 400 V)
Input 230 Vrms, 50 Hz (7 kW needs ≥ 176 Vrms with the 60 A current limit)
PFC totem-pole, 80 kHz fast leg (SiC C3M0021120K), L_boost 98 µH, DC link 1.88 mF / 400 V
LLC 2 × full bridge in parallel, L_r 1.55 µH, C_r 1.2 µF (f_r 116 kHz), L_k 5 µH, 1:1, diode or synchronous rectifier
Result, ideal switches, 230 V / 7 kW / 400 V PF 0.995, grid current THD 1.3 %, DC link 400 V ± 20 V, output 399.8 V

Documentation

Section Doc
Simulation: model, configurations, modes, sweep, results doc/simulation.md
LLC stage and LLC controller doc/llc.md
LTspice schematics doc/ltspice.md
Review: what was fixed and what is still open doc/review.md

The PFC power stage, EMI filter, switches, sensors and PFC controller are the library blocks documented in 0049_SP_BTP_PFC_1KW/doc; this repo scales them to 7 kW.

Quick start

  1. Start PLECS with the XML-RPC server on port 1080 (Preferences → General).

  2. Set the parameters in lib/vars.py. In main.py, set the sweep and the model depth with MODE = 'ideal' | 'real'.

  3. Run:

    python main.py        # OBC transient sweep -> data/html/Html_<run>.html
    python analysis.py    # HV DC filter AC sweep -> data/html/AC_<run>.html

LTspice: open the .asc files in ltspice/ and run them (results are git-ignored).

Repository layout

main.py             entry point: sweep definition, model mode and run flags          [system specific]
analysis.py         AC sweep of the HV DC filter                                     [system specific]
asset/              schematics and screenshots used in the docs
doc/                documentation
model/
  OBC.plecs                 full charger (library blocks + PFC CTRL + LLC CTRL configurations)
  HV_Filter_Analysis.plecs  DC filter, AC sweep 'DC Filter AC Sweep'
  AC_Filter_Analysis.plecs  input filter, stand-alone (init commands)
  Trafo.plecs               LLC transformer, stand-alone (init commands)
lib/
  vars.py           model paths, parameters, configurations, modes                   [system specific]
  calc.py           signal math (PMath) + derived parameters per sweep point (Derived, [system specific])
  plecs.py          PLECS XML-RPC interface, scopes, result folders, sweep points, code generation + RT Box
  process.py        HTML report and result matrices (PPlots), sweep log (PLog)
  signals.py        result column names / units read from the model
  standalone.py     library-free copy of the model (breaklink.py)
ltspice/
  ac_input_filter/  EMI filter variants, AC analysis
  trafo/            transformer model (magnetizing, core loss, leakage)
  llc/              LLC tank, open-loop LLC (diode / synchronous rectifier), 450 W closed-loop LLC
  results/          LTspice outputs (git-ignored)
data/               sweep outputs (git-ignored)

lib/ is the same library as 0049_SP_BTP_PFC_1KW: only vars.py, Derived in calc.py and the two entry points are specific to this system.

Copyright and Licensing