Skip to content

About

a very light but very powerful auto clicker software, built on rust

Resources

Contributing

Stars

1 star

Watchers

0 watching

Forks

Latest commit

 

History

10 Commits

Folders and files

Repository files navigation

MegaClicker

A very light but very powerful auto clicker for Windows 10/11 x64, written in Rust. MegaClicker runs in a console with a small notification-area icon and a native settings window, uses configurable global hotkeys, and keeps all behavior in one small TOML file. It has no network access and no telemetry.

What it is

MegaClicker's MVP does one job: click reliably at a configured interval, under global hotkey control, with measurable timing and clean shutdown. Everything needed for that is included; everything else is deliberately left out.

  • Configurable global function keys start/stop clicking, switch profiles, and quit, even when another window is focused. Defaults are F6, F7, and F8.
  • Named profiles store alternate click settings in separate TOML files and can be switched at runtime with F7.
  • A tray icon mirrors the hotkeys: start/stop, switch profile, open settings, open the config or profiles folder, and exit.
  • A native settings window edits every click setting and rebinds all three hotkeys without touching the TOML file by hand.
  • Optional interval randomization spreads clicks within a percentage of interval_ms; optional cursor jitter moves the pointer within a configured radius of where each session started.
  • Ctrl+C also quits cleanly, stopping the click thread.
  • Interval, interval jitter, mouse button, single/double click, cursor jitter, click limit, and start delay are configurable in %APPDATA%\MegaClicker\config.toml.
  • --dry-run follows the real timing and counts clicks without sending input.
  • A named mutex prevents two copies from running at once.
  • A dedicated click thread with an atomic stop flag and condition-variable wake keeps idle CPU at zero and makes stopping effectively instant.

Not in the MVP

No click sequences, multi-point macros, recording/playback, scheduler, installer, auto-start, updater, localization, analytics, crash reporting, network features, or non-Windows builds. The randomization options are not anti-detection features; see Known limitations.

Requirements

  • Windows 10 or Windows 11, x64.
  • Rust stable with the MSVC toolchain (stable-x86_64-pc-windows-msvc) and the Visual Studio C++ Build Tools.
  • No administrator privileges are required.
  • No runtime dependencies. The release binary is self-contained.

Build

From a clean checkout:

cargo build --release

The binary is written to:

target\release\megaclicker.exe

Quality gates used by this project:

cargo fmt --check
cargo clippy --all-targets -- -D warnings
cargo test
cargo build --release

Install

There is no installer. Copy megaclicker.exe anywhere you like and run it. To remove MegaClicker, delete the executable and optionally the config folder %APPDATA%\MegaClicker.

Usage

.\megaclicker.exe
.\megaclicker.exe --dry-run
.\megaclicker.exe --config .\my-config.toml
.\megaclicker.exe --profile gaming
.\megaclicker.exe --list-profiles
.\megaclicker.exe --version
Flag Meaning
--config <PATH> Use an existing config file instead of the default. A missing file is an error, so typos are not silently replaced. Profiles are stored in a profiles folder next to this file.
--profile <NAME> Start with the named profile, creating it with defaults if the file does not exist.
--list-profiles Print the default profile and every named profile, then exit.
--dry-run Count clicks and use the real timing, but do not send mouse input.
--version Print the version and exit.
--help Print CLI help and exit.

Hotkeys

Key Action
Configured toggle_hotkey (default F6) Start clicking, or stop the current session. Works globally, even when MegaClicker is not the focused window.
Configured profile_hotkey (default F7) Switch to the next usable profile.
Configured quit_hotkey (default F8) Quit MegaClicker.
Ctrl+C Quit MegaClicker.

Toggle presses within 250 ms are ignored (debounce). Starting while already running is a no-op; stopping while stopped is a no-op. All three hotkeys can be set to different function keys from F1 through F12 in the configuration.

Tray menu

MegaClicker adds a notification-area icon while it runs. Right-click it for:

Item Action
Start / stop clicking Same as the toggle hotkey.
Next profile Same as the profile hotkey.
Settings... Opens the settings window.
Open config Opens config.toml in the default editor.
Open profiles folder Opens the profiles folder, creating it if needed.
Exit Quits MegaClicker cleanly.

Double-clicking the icon also opens the settings window. If the shell refuses to add the icon, MegaClicker prints a warning and continues console-only; the settings window can only be opened from the tray icon, so edit config.toml by hand in that case.

Settings window

The settings window is a native Win32 dialog-sized window created on first use and reused afterwards, so it adds nothing to startup. It has no dependencies and no resizable layout: one row per setting, three hotkey drop-downs listing F1 through F12, and Save/Cancel buttons.

Control Edits
Interval (ms) interval_ms
Interval jitter (%) interval_jitter_percent
Mouse button button
Click type click_type
Cursor jitter (px) cursor_jitter_px
Click limit (0 = unlimited) click_limit
Start delay (s) start_delay_seconds
Toggle / Quit / Profile hotkey toggle_hotkey, quit_hotkey, profile_hotkey

What Save does, in order:

  1. Validates every field with the same rules as the TOML loader. Invalid input shows an error box naming the field and its range, and the window stays open with your edits intact.
  2. Rebinds the global hotkeys. If another application owns a chosen key, an error box explains which key is unavailable, the previous hotkeys keep working, and nothing is written.
  3. Writes all values back to config.toml using the same commented layout as the first-run file, so the file stays hand-editable. The file is replaced atomically. If writing fails, the hotkeys are restored to their previous keys.
  4. Closes the window and prints the new settings and hotkeys to the console.

The window always edits config.toml, which is the default profile. When a named profile is active, its click settings stay in effect and only the hotkeys change immediately; the saved click settings apply the next time the default profile is used. Opening the window stops a running session so the clicks do not land on the settings window itself.

If the config file was loaded with --config, that file is the one the settings window writes to.

Startup output

MegaClicker 0.5.0 - lightweight auto clicker for Windows
Config: C:\Users\you\AppData\Roaming\MegaClicker\config.toml (created with defaults)
Profile: default (click settings from config.toml)
  interval_ms              = 100
  interval_jitter_percent  = 0
  button                   = left
  click_type               = single
  cursor_jitter_px         = 0
  click_limit              = 0 (unlimited)
  start_delay_seconds      = 0
  toggle_hotkey            = F6
  quit_hotkey              = F8
  profile_hotkey           = F7
Mode: live (clicks are sent at the current cursor position)
Hotkeys: F6 = start/stop | F7 = next profile | F8 = quit | Ctrl+C = quit
Ready. Press F6 to start or stop, F7 to switch profile, F8 to quit.
Tray icon: double-click (or Settings...) opens the settings window.

While running, MegaClicker prints the start settings, a status line every five seconds, and a final stop report with the click count, elapsed time, average CPS, and measured stop latency.

Exit codes

Code Meaning
0 Normal shutdown from the quit hotkey, the tray menu, or Ctrl+C.
1 Configuration, I/O, or unexpected startup error.
2 A required global hotkey (toggle, profile, or quit) is already used by another application.
3 Another MegaClicker instance is already running in this Windows session.

Configuration

Location and lifecycle

The default config file is:

%APPDATA%\MegaClicker\config.toml

On first run MegaClicker creates the folder and the file, including comments that document every setting and its valid range. The committed config.toml in this repository is the exact file that is written on first run.

The config is read once at startup. Editing it while MegaClicker is running has no effect; restart MegaClicker to apply changes. The settings window is the exception: it rewrites this file and keeps the file, the hotkeys, and the next session in sync. Delete the file and run MegaClicker again to regenerate the defaults.

--config <PATH> reads an existing file instead of the default. It does not auto-create a missing file.

Settings

Key Default Allowed values Meaning
interval_ms 100 1–1000 Base time between the start of consecutive clicks, in milliseconds.
interval_jitter_percent 0 0–50 Randomize each interval by up to this percentage of interval_ms. 0 disables it.
button "left" "left", "right", "middle" Mouse button to press.
click_type "single" "single", "double" One press/release pair, or two rapid pairs per click action.
cursor_jitter_px 0 0–100 Before each click, move the cursor to a random point within this many pixels of where the session started. 0 keeps it in place.
click_limit 0 0–1000000000 Stop after this many click actions. 0 means unlimited.
start_delay_seconds 0 0–5 Delay before the first click after each start. Applies only to the first click.
toggle_hotkey "F6" "F1"–"F12" Global key to start/stop clicking. Must differ from the other hotkeys.
quit_hotkey "F8" "F1"–"F12" Global key to quit. Must differ from the other hotkeys.
profile_hotkey "F7" "F1"–"F12" Global key to switch to the next profile. Must differ from the other hotkeys.

String values are matched case-insensitively. Unknown keys are rejected rather than ignored, so typos cannot silently fall back to a default.

A double click action sends two rapid down/up pairs and counts as one click action towards click_limit. This keeps the limit independent of the button event count.

Example

# Time between the start of consecutive clicks, in milliseconds.
# Allowed: 1-1000
interval_ms = 100

# Randomize each interval by up to this percentage. 0 disables randomization.
# Allowed: 0-50
interval_jitter_percent = 0

# Allowed: "left", "right", "middle"
button = "left"

# Allowed: "single", "double"
click_type = "single"

# Before each click, move the cursor within this many pixels of where clicking
# started. 0 keeps the cursor in place.
# Allowed: 0-100
cursor_jitter_px = 0

# 0 = unlimited. Allowed: 0-1000000000
click_limit = 0

# Allowed: 0-5
start_delay_seconds = 0

# Global function keys; they must all differ from each other.
# Allowed: "F1" through "F12"
toggle_hotkey = "F6"
quit_hotkey = "F8"
profile_hotkey = "F7"

Profiles

A profile is a named set of click settings stored as its own TOML file:

%APPDATA%\MegaClicker\profiles\gaming.toml

Profiles contain only interval_ms, interval_jitter_percent, button, click_type, cursor_jitter_px, click_limit, and start_delay_seconds. Hotkeys are global: they stay registered when profiles change. A missing profile file is created with defaults the first time it is selected:

.\megaclicker.exe --profile gaming
.\megaclicker.exe --list-profiles

Use the configured profile_hotkey (default F7) to cycle through default and the named profiles in case-insensitive alphabetical order. Switching applies the new click settings to the next session; a session that is already running keeps the settings it started with. Invalid profile files are reported and skipped while cycling.

Profile names are limited to 32 characters and may contain ASCII letters, digits, -, and _ only. default is reserved for the click settings in config.toml. The active profile is not persisted: after a restart MegaClicker uses the base configuration unless --profile is passed again.

Invalid configuration

Invalid values stop startup with an error that names the field and its valid range, for example:

[error] config file: C:\Users\you\AppData\Roaming\MegaClicker\config.toml: invalid `interval_ms` = 0; expected an integer from 1 to 1000 (milliseconds)

A TOML syntax or type error is also reported before any input or hotkey activity begins.

Behavior and timing

  • Absolute scheduling. Click deadlines are derived from a fixed session origin, so a slow click does not accumulate drift over time. interval_ms is measured from the start of one click to the start of the next.
  • Interval jitter. With interval_jitter_percent above zero, each step draws a new interval uniformly between interval_ms × (100 − jitter)% and interval_ms × (100 + jitter)%. The configured interval never falls below 1 ms. Jitter is sampled per step from a small built-in PRNG, so it is not a guarantee against detection and the average rate stays near interval_ms.
  • Cursor jitter. With cursor_jitter_px above zero, the first click of a session remembers the cursor position, and every click moves the pointer to a random point within that many pixels horizontally and vertically before pressing. The pointer jumps rather than glides, and each session re-anchors. With 0, MegaClicker never calls GetCursorPos or SetCursorPos.
  • One click thread. A single dedicated thread runs the click loop. Idle MegaClicker blocks on a condition variable and uses effectively no CPU.
  • Fast stop. A stop request sets an atomic flag. Long waits are split into at most 5 ms native sleeps, and the final 500 µs of each deadline is a short spin, so the worker notices a stop within a few milliseconds. Shutdown joins the worker before the process exits.
  • Start delay. The delay applies once per start, before the first click, and is interruptible by the toggle hotkey, the quit hotkey, or Ctrl+C.
  • Click limit. When the configured limit is reached, clicking stops automatically and the final count is printed.
  • Dry-run. --dry-run exercises the same thread, scheduling, stop path, and click accounting, but substitutes a no-op input sink. It is safe on any machine, including remote sessions.

Performance

Measured on this machine with the release build, using a harness that drives the real binary through injected F6/F8 hotkeys in --dry-run mode. Timing rows use randomization disabled; with jitter enabled the mean stays near the configured interval, but individual gaps vary by design. Targets are from the MVP specification.

Metric Target Measured
Interval accuracy, 10 CPS ±10% 10.3 CPS (30 clicks in 2.90 s)
Interval accuracy, 100 CPS ±10% 100.1 CPS (1001 clicks in 10.00 s)
Stop latency from F6 < 50 ms 1.46 ms
Idle CPU < 0.5% 0.00% of one core (below timer resolution)
Clicking CPU at 50 CPS < 5% 0.10% of one core (31.25 ms in 30 s)
Resident memory < 25 MB 7.4 MB idle, 11.3 MB with the settings window open
Stripped release binary < 4 MB 0.784 MB (822,272 bytes)

CPU figures come from 30-second TotalProcessorTime samples while idle and while clicking at 50 CPS, plus a 10-second sample with the settings window open. Idle and settings-open samples accrued 0 ms, i.e. below the 15.6 ms Windows timer granularity; the clicking sample accrued 31.25 ms. Private memory was 1.5 MB idle and 2.1 MB with the settings window open. Working set is reported for a hidden settings window and again with the window open. The reported CPS is clicks / session duration, so very short sessions read slightly high (for example, 10 clicks at a 50 ms interval finished in 450 ms).

A separate live-input test sent real SendInput events to a WinForms window: 10 single-click actions produced 10 MouseDown events, and 5 double-click actions produced 5 MouseDoubleClick events, confirming end-to-end delivery. With cursor_jitter_px = 20, 25 live clicks visited 23 distinct positions, all within 17 px horizontally and 20 px vertically of the session anchor.

Timing above 100 CPS is best effort: Windows timer resolution, input queueing, and the target application's message loop dominate at that point.

Known limitations and MVP trade-offs

  • Windows only. The MVP targets Windows 10/11 x64 and uses Win32 directly.
  • Console and tray icon. The console window must stay open; closing it terminates MegaClicker. The tray icon mirrors the main actions and opens the settings window. Without a working tray icon the settings window cannot be opened, so edit config.toml by hand instead.
  • Function-key hotkeys only. The toggle, profile, and quit hotkeys can be selected from F1–F12, either in config.toml or in the settings window, but modifiers and arbitrary keys are not supported.
  • Cursor movement is jitter, not a path. With cursor_jitter_px above zero, each click jumps to a random point within a square around the position where the session started. It does not glide, follow a recorded path, or move to multiple targets. Without it, clicks go wherever the pointer currently is.
  • Randomization is not a guarantee. interval_jitter_percent and cursor_jitter_px make output less uniform, but they are not designed to evade anti-cheat, bot detection, or monitoring. Use MegaClicker only where synthetic input is allowed.
  • Base config requires restart. Values edited in config.toml by hand are read once at startup. Changes made through the settings window are applied immediately. Named profiles are re-read whenever they are selected.
  • Settings edit the default profile. The window always saves to the base config. A named profile keeps its own click settings; only hotkeys change immediately while one is active.
  • Active profile is not persisted. After a restart MegaClicker uses the base configuration unless --profile is passed again.
  • Elevation / UIPI. Windows blocks synthetic input sent from a lower integrity process to an elevated window. If clicks do not reach an administrator window, run both at the same privilege level. MegaClicker reports SendInput failures when Windows rejects them.
  • Anti-cheat and protected processes. Some games and security tools block synthetic input by design. MegaClicker does not attempt to bypass them.
  • Double-click semantics. A double action counts as one click action towards click_limit; it sends two rapid button press/release pairs.
  • Single instance per Windows session. The named mutex is local to the logged-in session, so two different users can each run one copy.
  • Best effort above 100 CPS. The specification's accuracy target covers 10–100 CPS. At 1 ms intervals, OS scheduling and input injection become the limiting factors.
  • No persistence beyond config. Counters and session history are not saved.
  • No auto-start or updater. Start MegaClicker manually, or use Windows Task Scheduler yourself if you need that (out of MVP scope).

Safety and privacy

  • MegaClicker makes no network connections, has no telemetry, no crash reporting, and no auto-update mechanism.
  • It writes only the base config file and profile files under %APPDATA%\MegaClicker.
  • Synthetic mouse input is sent only while a session is running, and the cursor is moved only when cursor_jitter_px is above zero.
  • --dry-run never calls SendInput.
  • All unsafe Rust is confined to three platform modules: src/input.rs, which wraps synthetic input, global hotkeys, the message wait and pump, the named mutex, and the console Ctrl+C handler; src/tray.rs, which wraps the notification-area icon, its hidden window, the popup menu, and ShellExecuteW; and src/gui.rs, which wraps the settings window and its controls. Each unsafe block has a SAFETY: comment. No other module contains unsafe.

Project layout

src/
  main.rs             startup, wiring, console UI, shutdown
  cli.rs              command-line arguments
  config.rs           load, validate, render, save, create defaults, resolve path
  profile.rs          named profile storage, discovery, cycle selection
  hotkey.rs           configurable global hotkeys, rebinding, conflict errors, debounce
  engine.rs           click thread, state machine, scheduling, interval jitter, tests
  input.rs            Win32 input, cursor, hotkey, message pump, and mutex wrappers
  random.rs           small built-in PRNG for jitter
  tray.rs             notification-area icon, popup menu, shell launching
  gui.rs              native settings window and hotkey rebinding
  single_instance.rs  named-mutex single-instance guard
config.toml           default config written on first run

Development

cargo fmt
cargo clippy --all-targets -- -D warnings
cargo test
cargo build --release

Unit tests cover configuration parsing and every range error, TOML rendering and round-tripping, saving and reloading the config file, settings-window field validation, hotkey validation, profile creation and discovery, profile cycling with broken files, click-limit accounting, debounce behavior, start/stop no-ops, start delay, applying a new config to the next session, interval jitter bounds and variability, PRNG determinism, cursor jitter reaching the input sink, tray string handling, and a dry-run session that reaches its limit.

To measure timing safely without clicking anything:

.\target\release\megaclicker.exe --dry-run --config .\config.toml

Then press F6 to start and F6 again to stop. The stop report prints the click count, elapsed time, average CPS, and measured stop latency. Press F7 to cycle profiles and F8 to exit.

Roadmap

Done:

  • Configurable global hotkeys (v0.1.1)
  • Multiple profiles and per-profile config switching (v0.2.0)
  • Tray icon with a native menu (v0.3.0)
  • Settings GUI, with hotkey rebinding (v0.4.0)
  • Randomized intervals and cursor jitter, with clear disclaimers (v0.5.0)

Planned:

  • Click sequences, multi-point macros, recording/playback
  • Installer, auto-start, updater
  • Localization
  • macOS/Linux support

License

MIT. See LICENSE. The license is not modified by this project.

About

a very light but very powerful auto clicker software, built on rust

Resources

Contributing

Stars

1 star

Watchers

0 watching

Forks

Releases

Packages

Contributors

Languages